Concept 04 / 04Redox Reactions
Redox Titrations and the n-Factor of Oxidising and Reducing Agents
Using redox reactions in volumetric analysis: n-factor (valence factor) of oxidants and reductants, KMnO4 in acidic, neutral and basic media, dichromate titrations, iodometry and iodimetry with thiosulfate, the law of equivalence, and choice of acid and indicator.
Redox titrations determine the amount of an oxidant or reductant by titrating it against a standard solution of the other. The key idea is the law of equivalence: at the end point, the number of electrons given by the reductant equals the number accepted by the oxidant.
n-factor (valence factor). For an oxidant or reductant, the n-factor is the number of electrons gained or lost per formula unit (the total change in ON per formula unit). Then
equivalents moles n-factor, equivalent weight , normality molarity n,
and at the equivalence point , or equivalently .
Common n-factors.
: acidic (to ), neutral or weakly basic (to ), strongly basic (to ) (see figure).
(acid): . : . (oxalate to ): . : (as oxidant or reductant). to : . to : .
For a species where two elements change (as in oxidised by : Fe and ), add the changes: n .
Permanganometry. is used in dilute . It acts as its own indicator: the first excess drop gives a permanent pink colour. HCl is avoided because permanganate oxidises to ; is avoided because it is itself an oxidant. Oxalic acid titrations are warmed to about because the reaction is slow until (an autocatalyst) forms. is not a primary standard and is standardised against oxalic acid or Mohr's salt.
Dichromatometry. is a primary standard (pure, stable) and can be used in the presence of HCl. An external or internal indicator (diphenylamine) is needed, because the orange-to-green change is not sharp.
Iodometry and iodimetry. Iodimetry: direct titration with standard (for reductants such as , ). Iodometry: an oxidant liberates from excess KI, and the is titrated with standard sodium thiosulfate using starch (blue to colourless):
; .
So correspond to thiosulfate.
Key Takeaways:
- n-factor electrons transferred per formula unit; equivalents moles n.
- At equivalence: .
- : n , , in acidic, neutral, strongly basic media.
- is a self-indicator; use , not HCl or .
- Pitfall: in iodometry, relate the oxidant to thiosulfate through the liberated , not directly.
Brain-Teaser 1: What volume of is needed to oxidise of in acid?
Solution: Equivalents of : . normality . Volume .
Brain-Teaser 2: How many moles of (acidic) are needed to oxidise one mole of ferrous oxalate completely?
Solution: Ferrous oxalate loses from iron and from oxalate: n , so of electrons. Each accepts : .
Brain-Teaser 3: A sample of is treated with excess KI, and the liberated iodine needs of . Find the mass of in the sample.
Solution: Thiosulfate: , which reacts with , liberated by . Mass .
Practice this concept
Free · no account required · instant solutions